What the heat transfer coefficient is
The heat transfer coefficient says how easily heat crosses a surface, per square metre of it and per degree of temperature difference: a low coefficient means a well-insulated wall, a high coefficient means a bare metal plate in moving water. It is the number behind every window rating and heat-exchanger sheet. Building work calls it the U-value (or U-factor) in watts per square metre kelvin (W/(m²·K)); American work quotes it in Btu per hour square foot degree Fahrenheit (Btu/(h·ft²·°F)); older heat-transfer books quote kilocalories and calories — and all of them measure the same quantity, so a window at U = 0.3 W/(m²·K) in one catalogue is 0.0528 Btu/(h·ft²·°F) in the other. This page restates any heat transfer coefficient in all ten units at once, worked through W/(m²·K) with every factor defined, and answers the question the conversion alone cannot: what thermal resistance does this coefficient mean, and how much heat crosses an area you enter at a temperature difference you enter?

The formula
answer = W/(m²·K) ÷ (W/(m²·K) in one "to" unit)
thermal resistance = 1 ÷ coefficient
heat passed = coefficient × area × temperature difference
Four terms, all visible on the page. value is the number you enter. W/(m²·K) in one "from" unit is the definition of the unit you are converting from: 1 for the watt per square metre kelvin itself and for the watt per square metre degree Celsius, 1,000 for the kilowatt version, 10,000 for the watt per square centimetre degree Celsius, 1.163 for the kilocalorie per hour version, 4.1868 for the calorie per second version, 5.6782633411 for the Btu per hour version (IT), 5.6744644739 for the Btu(th) version, 340.6958004668 for the Btu per minute version and 20,441.7480280086 for the Btu per second version. answer is the result in the unit you asked for. thermal resistance is the reciprocal of the coefficient, and heat passed is the coefficient times the area times the temperature difference, in watts, so the window rating on the spec sheet turns into the watts actually leaving the room.
Worked example
Convert 0.3 W/(m²·K) to Btu/(h·ft²·°F) — a well-insulated wall, restated for an American window-and-wall table — the way the tool does it.
Step 1 — get to W/(m²·K). The input is already in W/(m²·K), so the base value is 0.3 W/(m²·K) itself.
Step 2 — divide by the target factor. One Btu(IT)/(h·ft²·°F) is 5.6782633411 W/(m²·K), so 0.3 ÷ 5.6782633411 = 0.0528.
Step 3 — read the display. The headline reads 0.0528 Btu(IT)/(h·ft²·°F), and the detail line shows the working: 0.3 W/(m²·K) = 0.0528 Btu(IT)/(h·ft²·°F) — worked through W/(m²·K): 0.3 W/(m²·K) ÷ the Btu per hour square foot degree Fahrenheit (IT) factor. The full table for this example reads: 0.3 W/(m²·K), 3.00e-04 kW/(m²·K), 0.3 W/(m²·°C), 3.00e-05 W/(cm²·°C), 0.258 kcal(IT)/(h·m²·°C), 0.0717 cal(IT)/(s·m²·°C), 0.0528 Btu(IT)/(h·ft²·°F), 0.0529 Btu(th)/(h·ft²·°F), 8.81e-04 Btu(IT)/(min·ft²·°F) and 1.47e-05 Btu(IT)/(s·ft²·°F). The extra line, at the default area of 20 m² and temperature difference of 20 K, reads: That is a thermal resistance of 3.3333 m²·K/W. Through 20 m² at a temperature difference of 20 K it passes 120 W.
Check it. Multiplying back, 0.0528 Btu(IT)/(h·ft²·°F) × 5.6782633411 = 0.3 W/(m²·K) to the displayed rounding — the exact value multiplies back to 0.3 exactly, because the Btu(IT) definition is exact. The extra line checks the same way: 3.3333 m²·K/W × 0.3 W/(m²·K) = 1, the reciprocal identity, and 120 W ÷ (20 m² × 20 K) = 0.3 W/(m²·K), the coefficient we started from.
Conversion table
The conversions window specs, wall tables and heat-exchanger sheets reach for most, each one the same two steps as the example:
| From | To |
|---|---|
| 1 W/(m²·K) | 0.1761 Btu(IT)/(h·ft²·°F) |
| 2 W/(m²·K) | 0.3522 Btu(IT)/(h·ft²·°F) |
| 10 W/(m²·K) | 1.7611 Btu(IT)/(h·ft²·°F) |
| 100 W/(m²·K) | 17.61 Btu(IT)/(h·ft²·°F) |
| 5.6783 W/(m²·K) | 1 Btu(IT)/(h·ft²·°F) |
| 2.8 W/(m²·K) | 0.4931 Btu(IT)/(h·ft²·°F) |
| 13.1 W/(m²·K) | 2.307 Btu(IT)/(h·ft²·°F) |
| 500 W/(m²·K) | 88.06 Btu(IT)/(h·ft²·°F) |
Three everyday cross-checks for the scale, each one the same two steps: one Btu(IT)/(h·ft²·°F) is 5.6783 W/(m²·K), the reciprocal of the worked example's step; a double-glazed window at U = 2.8 W/(m²·K) is a thermal resistance of 0.3571 m²·K/W, since 1 ÷ 2.8 = 0.3571; and still air sits at roughly 10 W/(m²·K) while moving water reaches 500 to 10,000 W/(m²·K) — a fifty-fold gap that is why a water-cooled plate and an air-cooled plate are different engineering problems, and why the 500 W/(m²·K) row reads 88.06 Btu(IT)/(h·ft²·°F).
Reading the result, and its limits
Four distinctions keep this page honest. First, U-value and the film coefficient h share units but not meaning: h describes one fluid film against a surface, while U describes a whole assembly — films plus layers together — so a textbook h of 10 W/(m²·K) for still air must never be quoted as the U-value of a wall. Second, U-value is the inverse of thermal resistance, not a rival to it: the resistance page and this page are the same physics read backwards, and the extra line exists so the two are never confused — 0.3 W/(m²·K) is 3.3333 m²·K/W, always. Third, the Btu(IT) and Btu(th) versions differ by only about 0.07%, but a table that does not say which one it means cannot be checked against this page — so both are carried separately, and the worked example's 0.0528 (IT) against 0.0529 (th) shows the gap at real scale. Fourth, the heat-passed line assumes one steady coefficient over the whole area: real walls have cold bridges, real exchangers have fouling, and a coefficient that varies with temperature or flow makes 120 W an estimate for the stated conditions, not a meter reading.
Related tools: Thermal Resistance Converter — R-value to RSI, m²·K/W to ft²·°F·h/Btu, clo and tog — every answer in all ten units; Heat Flux Converter — W/m² to Btu/h·ft², kcal/h·ft², W/in² and more — every answer in all ten units; Thermal Conductivity Converter — W/m·K to Btu/h·ft·°F, Btu·in/h·ft²·°F, cal/s·cm·°C and more — every answer in all ten units.
Frequently asked questions
How do I convert a U-value from W/(m²·K) to Btu/(h·ft²·°F)?
Divide by 5.6783. A wall at 0.3 W/(m²·K) is 0.3 ÷ 5.6783 = 0.0528 Btu(IT)/(h·ft²·°F), the worked example on this page. To go the other way, multiply the Btu figure by 5.6783.
What is the difference between U-value and R-value?
They are reciprocals: R = 1 ÷ U. A wall at 0.3 W/(m²·K) has a thermal resistance of 3.3333 m²·K/W. Lower U means better insulation, exactly as higher R does, and the extra line on this page gives you both.
Is the heat transfer coefficient the same as thermal conductivity?
No. Thermal conductivity (W/(m·K)) is a property of a material, while the heat transfer coefficient (W/(m²·K)) describes a surface or a whole assembly, per square metre. They differ by a length: divide a layer's conductivity by its thickness to get that layer's contribution to the assembly.
How much heat does a U-value actually pass?
Multiply U × area × temperature difference. At the worked example's U = 0.3 W/(m²·K), through 20 m² at a 20 K difference, the heat passed is 0.3 × 20 × 20 = 120 W. Enter any area and difference and the extra line does that multiplication for you.