What heat capacity is
Heat capacity says how much heat one particular object soaks up for each degree it warms: a large water tank has a huge heat capacity, a small copper coin has a tiny one, and the same material in two different sizes has two different heat capacities. It is the number behind every heating calculation for a real object. Europe and the science world quote joules per kelvin (J/K); calorimetry tables quote calories per degree Celsius (cal/°C); American engineering quotes Btu per degree Fahrenheit (Btu/°F); and energy-storage work quotes watt hours per kelvin (Wh/K) — and all of them measure the same quantity, so an object that is 1,899.1 J/K in one manual is 1 Btu/°F on the datasheet it arrives with. This page restates any heat capacity in all ten units at once, worked through J/K with every factor defined, and answers the two questions the conversion alone cannot: how much heat does warming this object by a temperature rise you enter actually take, and what is its specific heat for a mass you enter?
The formula
J/K = value × (J/K in one "from" unit)
answer = J/K ÷ (J/K in one "to" unit)
heat Q = heat capacity × temperature rise
specific heat c = heat capacity ÷ mass
Four terms, all visible on the page. value is the number you enter. J/K in one "from" unit is the definition of the unit you are converting from: 1 for the joule per kelvin itself and for the joule per degree Celsius, 1,000 for the kilojoule per kelvin, 1,000,000 for the megajoule per kelvin, 4.1868 for the calorie per degree Celsius (IT), 4,186.8 for the kilocalorie per degree Celsius (IT), 1,899.100534716 for the Btu per degree Fahrenheit (IT) and for the Btu per degree Rankine (IT), 1,897.83 for the Btu per degree Fahrenheit (th), and 3,600 for the watt hour per kelvin. answer is the result in the unit you asked for. heat Q is the heat capacity times the temperature rise you enter, in joules, so the datasheet figure turns into the energy a heater must actually supply. specific heat c is the heat capacity divided by the mass you enter, in joules per kilogram kelvin, so the whole-object figure turns back into the per-mass figure materials tables quote.
Worked example
Convert 1 Btu(IT)/°F to joules per kelvin — the unit jump every American furnace manual forces on a metric reader — the way the tool does it.
Step 1 — get to J/K. One Btu(IT)/°F is 1,899.100534716 J/K, so 1 × 1,899.100534716 = 1,899.1 J/K as displayed.
Step 2 — read the display. The headline reads 1,899.1 J/K, and the detail line shows the working: 1 Btu(IT)/°F = 1,899.1 J/K — worked through J/K: 1,899.1 J/K ÷ the Joule per kelvin factor. The full table for this example reads: 1,899.1 J/K, 1,899.1 J/°C, 1.8991 kJ/K, 0.0019 MJ/K, 453.59 cal(IT)/°C, 0.4536 kcal(IT)/°C, 1 Btu(IT)/°F, 1.0007 Btu(th)/°F, 1 Btu(IT)/°R and 0.5275 Wh/K. The extra line, at the default temperature rise of 10 K and mass of 2 kg, reads: Heat to warm this object by 10 K: 18,991.01 J (18.99 kJ). Per unit mass, this is a specific heat of 949.55 J/(kg·K) — heat capacity divided by mass.
Check it. Multiplying back, 1,899.1 J/K ÷ 1,899.100534716 = 1 Btu(IT)/°F, and the heat line checks the same way: 18,991.01 J ÷ 10 K = 1,899.101 J/K, the heat capacity we started from to the displayed rounding.
Conversion table
The conversions furnace manuals, calorimetry tables and energy-storage sheets reach for most, each one the same two steps as the example:
| From | To |
|---|---|
| 100 J/K | 0.0527 Btu(IT)/°F |
| 1,000 J/K (1 kJ/K) | 0.5266 Btu(IT)/°F |
| 1 cal(IT)/°C | 4.1868 J/K |
| 1 kcal(IT)/°C | 4,186.8 J/K |
| 1 Btu(th)/°F | 1,897.83 J/K |
| 1 Btu(IT)/°R | 1,899.1 J/K |
| 1 Wh/K | 3,600 J/K |
| 1 MJ/K | 526.57 Btu(IT)/°F |
| 1 kg of water, 4,186.8 J/K | 2.2046 Btu(IT)/°F |
| 5 kg of water, 20,934 J/K | 11.02 Btu(IT)/°F |
Three everyday cross-checks for the scale, each one the same two steps: warming 1 kg of water by 10 K takes 4,186.8 × 10 = 41,868 J, which is 41.87 kJ — the figure every kettle calculation starts from; a 2 kg aluminium block at 897 J/(kg·K) has a heat capacity of 1,794 J/K, which converts to 0.9447 Btu(IT)/°F; and a 100 J/K sensor housing warmed by 50 K takes 5,000 J, a twentieth of the water litre's 10 K figure, which is why small instruments respond to a heater while a tank barely notices it.
Reading the result, and its limits
Four distinctions keep this page honest. First, heat capacity is for one particular object, not per unit mass: the specific heat of a material, in joules per kilogram kelvin, is its heat capacity divided by its mass — a different quantity with mass in the denominator — and it must never be fed into this converter as if it were a heat capacity; the companion specific heat capacity converter handles the per-mass figure. Second, the numerically equal family is not a coincidence: cal/°C, kcal/°C scaled by a thousand, Btu/°F and Btu/°R all read from the same water-based definitions, so water's figures scale cleanly across them. Third, IT and th differ by about 0.07%: a table that does not say which Btu it means cannot be checked to better than that, so this page carries both, separately. Fourth, heat capacity is not truly constant: it drifts with temperature and jumps at a phase change, so heat capacity × temperature rise is exact only while the capacity stays put — melting ice or boiling water needs the latent heat on top, which this page does not add.
Related tools: Specific Heat Capacity Converter — Specific heat J/(kg·K) to Btu/(lb·°F), cal/(g·°C) and CHU — every answer in all ten units; Thermal Conductivity Converter — W/m·K to Btu/h·ft·°F, Btu·in/h·ft²·°F, cal/s·cm·°C and more — every answer in all ten units; Energy Converter — Joules to calories, kcal to kJ, kWh to joules and BTU — every answer in all ten units, through the exact definitions.
Frequently asked questions
How do I convert J/K to Btu/°F?
Divide by 1,899.100534716. The worked example's 1 Btu(IT)/°F is 1,899.1 J/K, so 100 J/K is 100 ÷ 1,899.100534716 = 0.0527 Btu(IT)/°F. To go the other way, multiply by 1,899.100534716.
What is the difference between heat capacity and specific heat capacity?
Heat capacity is for one particular object — joules per kelvin — while specific heat capacity is per unit mass — joules per kilogram kelvin — and equals the heat capacity divided by the mass. A 2 kg object at 1,899.1 J/K has a specific heat of 949.55 J/(kg·K), and only the whole-object figure belongs in this converter.
Is J/°C the same as J/K?
For temperature differences, yes: a rise of 1 °C is exactly a rise of 1 K, so the two units read identically. For absolute temperatures the scales differ by 273.15, but this page converts differences, where the interval is what matters.
Why are Btu/°F and Btu/°R the same number?
Because a Rankine degree interval is exactly a Fahrenheit degree interval — both are 5/9 of a kelvin. The two scales differ only in where zero sits, and this page converts intervals, where the zero point cancels out.