Home › Text & Utility › Conductance Converter
Text & Utility

Conductance Converter

A multimeter says 2.5 mS, a datasheet says 2,500 µS, an old table says 0.0025 ℧ and a resistor catalogue says 400 Ω — four labels for one conductance. This page restates any conductance in kilosiemens, siemens, millisiemens, microsiemens, nanosiemens, mhos, absiemens and statsiemens at once, through the siemens definitions.

Free · No sign-up · Runs in your browser · First published 2026-10-25 · Updated November 2026

Everything converts through the siemens. The SI steps are exact powers of a thousand: 1 kS = 10³ S, 1 mS = 10⁻³ S, 1 µS = 10⁻⁶ S, 1 nS = 10⁻⁹ S. The older units are kept because they still appear in tables: 1 mho (℧) = 1 S exactly, 1 abS = 10⁹ S exactly in its own system, and 1 stS ≈ 1.112650056 × 10⁻¹² S. A conductance here is a size, so a negative value gets a clear error. The current line uses Ohm's law in its conductance form, I = G × V — it needs a voltage, which is why that field sits beside the converter rather than inside the table. Note the case: small m means milli, capital M would mean mega, a factor of a billion apart — and µS is not mS, a factor of a thousand apart.

Converted conductance
—

One conductance, four labels

Conductance is how easily current flows — G = current ÷ voltage, in siemens, where one siemens passes one ampere under one volt. It is the reciprocal of resistance: G = 1 ÷ R, so a 400 Ω resistor has a conductance of 1 ÷ 400 = 0.0025 S. The siemens itself is far too large for most circuit work, so real parts and measurements are labelled in its thousandths: millisiemens for resistors and small-signal work, microsiemens for sensor and leakage measurements, nanosiemens where the current is barely there at all. This page restates any conductance in all eight units at once, worked through the siemens with every factor defined, so a figure in any dialect can be read in any other. It also answers the question the conversion alone cannot: at a voltage you enter, how much current does this conductance pass?

Bar chart of everyday conductances in millisiemens: a 1 MΩ resistor 0.001, a 10 kΩ resistor 0.1, a 1 kΩ resistor 1, the worked example 400 Ω resistor 2.5 and a 100 Ω resistor 10
Everyday conductances in millisiemens, drawn as bars: the worked example below sits at 2.5 mS = 2,500 µS.

The formula

siemens = value × (siemens in one "from" unit)
answer = siemens ÷ (siemens in one "to" unit)

Two terms, both visible on the page. value is the number you enter. siemens in one "from" unit is the definition of the unit you are converting from: 10³ for the kilosiemens, 1 for the siemens itself, 10⁻³ for the millisiemens, 10⁻⁶ for the microsiemens, 10⁻⁹ for the nanosiemens, 1 for the mho, 10⁹ for the absiemens, and approximately 1.112650056 × 10⁻¹² for the statsiemens. answer is the result in the unit you asked for. Every SI step is a factor of exactly a thousand — that is the whole conversion, and it is why the millisiemens-to-microsiemens step never needs a calculator once the pattern is seen. The mho needs no step at all: it is ohm spelled backwards and it is the siemens under its old name, which is why the two rows of the table always agree. The statsiemens factor is approximate because it inherits the speed of light, while the absiemens factor is exact within its own system.

Worked example

Convert 2.5 millisiemens to microsiemens — the conductance of a 400 Ω resistor, and the value a bench meter reaches for first — the way the tool does it.

Step 1 — get to siemens. One millisiemens is 10⁻³ S, so 2.5 × 0.001 = 0.0025 S.

Step 2 — divide by the target factor. One microsiemens is 10⁻⁶ S, so 0.0025 ÷ 0.000001 = 2,500.

Step 3 — read the display. The page prints six decimals below 0.001, four below 10 and two above, so the headline reads 2,500 µS, and the detail line shows the working: 2.5 mS = 2,500 µS — worked through siemens: 0.0025 S ÷ the Microsiemens factor.

Check it. Multiplying back, 2,500 × 10⁻⁶ = 0.0025 S, the value we started from. The full table for this example reads: 0.000003 kS, 0.0025 S, 2.5 mS, 2,500 µS, 2,500,000 nS, 0.0025 ℧, 0 abS and about 2.25 × 10⁹ stS — the kilosiemens row is the page's six-decimal finest step applied to the exact 0.0000025 kS, the absiemens row reads 0 at that same step, the exact figure being 2.5 × 10⁻¹² abS, and the statsiemens figure is stated approximately because its factor is approximate. At 12 V, the current line reads 30 mA: 0.0025 × 12 = 0.03 A. And the resistance behind the example checks out: 1 ÷ 0.0025 = 400 Ω, which is the resistor a 2.5 mS reading describes.

Conversion table

The conversions bench work reaches for most, each one the same two steps as the example:

FromTo
1 S1,000 mS
1 mS1,000 µS
1 µS1,000 nS
25 mS25,000 µS
500 µS0.5 mS
0.5 S500 mS
2 S2,000 mS
1 mho1 S
1 S1 mho
1 nS0.001 µS
1 kS1,000 S
250 mS250,000 µS

The reciprocal link is what makes the table useful on a bench: a 1 kΩ resistor is 1 mS, a 100 Ω resistor is 10 mS, a 1 MΩ resistor is 1 µS and a 10 Ω resistor is 100 mS — each one is 1 divided by the resistance in ohms, and the worked example's own 400 Ω sits between the 1 kΩ and 100 Ω rows at 2.5 mS. Two current cross-checks for the voltage line, each one the same multiplication: 1 mS at 5 V passes 5 mA, and 10 mS at 12 V passes 120 mA. And the resistance converter's own worked example returns here: a 4.7 kΩ resistor is 1 ÷ 4,700 = 0.0002128 S, which is 0.2128 mS, passing 1.064 mA at 5 V.

Reading the result, and its limits

Three traps catch real work. First, the case and prefix traps: mS is not MS, and µS is not mS. A millisiemens is a thousandth of a siemens and a megasiemens is a million siemens — a billion apart — while a microsiemens is a thousandth of a millisiemens, so a sensor reading copied in the wrong one is wrong by exactly a thousand. Second, the conductance-versus-conductivity trap: conductance, in siemens, describes one particular component or path, while conductivity, in siemens per metre, describes a material — and the water-quality figures quoted in µS/cm are conductivity per centimetre, not conductance, so they cannot be dropped into this converter without the cell geometry that turns one into the other. Third, the zero-and-infinity ends: a conductance of zero is an open circuit passing nothing, and a resistance of zero — a short circuit — would be infinite conductance, which no real measurement ever is; the page treats zero as a valid reading and refuses negatives, because a negative conductance here would mean a sign error in the measurement, not a property of the part. Check the unit beside every reading before comparing it with a specification, and remember that a correct conversion of the wrong conductance is still the wrong conductance.

Related tools: Resistance Converter — Ohms to kiloohms, megaohms, milliohms and more — every answer in all eight units; Ohm's Law Calculator — Enter any two of voltage, current, resistance and power — get the other two, with the working; Electric Current Converter — Amps to milliamps, microamps and more — every answer in all eight units, plus the watts at your voltage.

Frequently asked questions

How many microsiemens are in a millisiemens?

Exactly 1,000. So 1 mS is 1,000 µS, 2.5 mS is 2,500 µS, and 1 S is 1,000,000 µS. Every SI step is a factor of a thousand: kilosiemens to siemens to millisiemens to microsiemens to nanosiemens.

What is the difference between mS and MS?

A factor of a billion. Small m means milli, one thousandth: 1 mS is 0.001 S. Capital M means mega, one million: 1 MS is 1,000,000 S. A 5 mS sensor reading and a 5 MS bulk figure are not remotely the same measurement, and the case of the letter is the whole difference. The same trap applies to µS versus mS, a factor of a thousand.

What is a mho?

The siemens under its old name: mho is ohm spelled backwards, and 1 ℧ = 1 S exactly. It survives in older tables and in the micromho, which is 1 µS. This converter carries it so an old table can be read without a second lookup.

How do I get conductance from resistance?

Divide 1 by the resistance in ohms: G = 1 ÷ R. A 400 Ω resistor is 1 ÷ 400 = 0.0025 S, which is 2.5 mS — the worked example on this page. A 4.7 kΩ resistor is 0.2128 mS, and a 1 MΩ resistor is 1 µS. The resistance converter on this site works the same pair from the other side.

Ahsan ul Haq
Editor, ToolFigure

Every ToolFigure calculator is checked against hand-worked examples before it is published — the same worked examples you can follow on each page. More about ToolFigure →

Related tools

Calculators that show their working

Free forever · No sign-up · Every result comes with its formula and a worked example.

Browse all tools